DynaMesh®

Tailored Implants made of PVDF

DynaMesh®-PRP soft
DynaMesh®-PRP visible

 

Pectopexy
Bilateral fixation on the pectineal ligament
Apical mesh repair

Anatomically and physiologically correct organ repositioning.
No reduction of pelvic volume via lateral fixation to the pectineal ligament. Prevention of defecation disorders, reduction of new lateral cystoceles. [32] The mobility of the vagina is retained.

Optimised safety with specific, standardised implantstructure of polyvinylidene fluoride (PVDF). Improved effective porosity and atraumaticwarp-knitted margins.Optimal dynamometry, shape stability anddefined elasticity

 

Fig. left:
Apical mesh repair following hysterectomy with
DynaMesh®-PRP soft / visible (03 cm x 15 cm)


DynaMesh®-PRP soft (1a) (03 cm x 15 cm)
DynaMesh®-PRP visible (1b) (03 cm x 15 cm)
DynaMesh®-PRP visible (2) (03cmx18cm)
DynaMesh®-PRP visible (3) (17cmx15cm)

  • No presacral preparation
  • Avoidance of injury to and irritation of nerves
  • Low risk of defecation disorders as there is no constriction of the lesser pelvis
  • Indication-related implant selection
  • Very good anatomical and physiological organ positioning
  • Safety through specific, standardised surgical techniques

DynaMesh®-PRP soft (03 cm x 15 cm) (1a)

DynaMesh®-PRP visible (03 cm x 15 cm) (1b)

For the surgical treatment of apical vaginal prolapse

Bilateral cervical or vaginal stump fixation as well as anterior uterus fixation with small uterus on the pectineal ligament.

Apical mesh repair
(vaginal stump / cervical stump) with
DynaMesh®-PRP soft / visible (03 cm x 15 cm)

Apical mesh repair for uterus preservation
(with small uterus) with
DynaMesh®-PRP visible (03 cm x 15 cm)
fixed uterus anterior


DynaMesh®-PRP visible (17 cm x 15 cm) (3)

DynaMesh®-PRP visible (03 cm x 18 cm) (2)

For the treatment of apical vaginal descent with simultaneous cystocele and rectocele repair

For the surgical treatment ofuterine prolapse with bilateral, posterior uterus fixation on the pectineal ligament (hysteropectopexy)

Bilateral cervical or vaginal stump fixation on the pectineal ligament. Anterior and posterior vaginal walltightening and reinforcement with extended implant structure.

Safe positioning of the uterus thanks to the special implant structure with exceptional dimensional stability and highly effective porosity.

Apical mesh repair
(vaginal stump / cervical stump) with
DynaMesh®-PRP visible (17 cm x 15 cm)
posterior and anterior fixation

Apical mesh repair for uterus preservation with
DynaMesh®-PRP visible (03 cm x 18 cm)
fixed uterus posterior


Product range

DynaMesh®-PRP soft (1a) 03 cm x 15 cm PV540315F1 Unit = 1 EA / BX
DynaMesh®-PRP soft (1a) 03 cm x 15 cm PV540315F3 Unit = 3 EA / BX
DynaMesh®-PRP visible (1b) 03 cm x 15 cm PV780315F1 Unit = 1 EA / BX

DynaMesh®-PRP visible (2) 03 cm x 18 cm PV780318F1 Unit = 1 EA / BX
DynaMesh®-PRP visibl (2) 03 cm x 18 cm PV780318F3 Unit = 3 EA / BX

DynaMesh®-PRP visible (3) 17 cm x 15 cm PV781715F1 Unit = 1 EA / BX
DynaMesh®-PRP visible (3) 17 cm x 15 cm PV781715F3 Unit = 3 EA / BX
Use and properties
Product DynaMesh®-PRP soft
(03 cm x 15 cm) (1a)

DynaMesh®-PRP visible
(03 cm x 15 cm) (1b)

DynaMesh®-PRP visible
(03 cm x 18 cm) (2)

DynaMesh®-PRP visible
(17 cm x 15 cm) (3)

Field of application vaginal prolapse (1a) (1b) (3) /

uterine prolapse (1a) (1b) (2)

Surgical method open / laparoscopic
Fixation to iliopectineal ligament suture
Optimal handling
gruene_punkte
Optimal patient safety
gruene_punkte
Optimal patient comfort
gruene_punkte
Atraumatic selvedges
gruene_punkte
Minimal use of material
gruene_punkte
High shape stability
gruene_punkte
Defined elasticity
gruene_punkte
visible technology
(1a) gruene_punkte (1b,2,3)

gruene_punkte Applies to all product sizes
Does not apply

Technical data
Product DynaMesh®-PRP soft
(03 cm x 15 cm) (1a)

DynaMesh®-PRP visible
(03 cm x 15 cm) (1b)

DynaMesh®-PRP visible
(03 cm x 18 cm) (2)

DynaMesh®-PRP visible
(17 cm x 15 cm) (3)

Polymer (monofilament) PVDF
Excellent biocompatibility
gruene_punkte
Minimal foreign body reaction
gruene_punkte
Reduced bacterial adherence
gruene_punkte
High ageing resistance
gruene_punkte
Optimal dynamometry
gruene_punkte
Reactive surface (a) [m²/m²] * 1.9
Maximum stability (b) [N/cm] 71
Elasticity (b) at 16 N/cm [%] 9
Textile porosity (c) [%] * 68
Effective porosity (c) [%] * 63
Effective porosity at 2.5 N/cm(c) [%] 63
Classification (d) 1a

gruene_punkte Applies to all product sizes

Legends for the technical data

* Central part of the mesh
(a) Ratio of implant reactive surface area (thread surface) to implant surface area
(b) measured in the strip tensile test
(c) Mühl method [6]
(d) Klinge’s classification [8]