DynaMesh®-PRP soft
DynaMesh®-PRP visible
Pectopexy
Bilateral fixation on the pectineal ligament
Apical mesh repair
Anatomically and physiologically correct organ repositioning.
No reduction of pelvic volume via lateral fixation to the pectineal ligament. Prevention of defecation disorders, reduction of new lateral cystoceles. [32]
The mobility of the vagina is retained.
Optimised safety with specific, standardised implantstructure of polyvinylidene fluoride (PVDF). Improved effective porosity and atraumaticwarp-knitted margins.Optimal dynamometry, shape stability anddefined elasticity
Fig. left:
Apical mesh repair following hysterectomy with
DynaMesh®-PRP soft / visible (03 cm x 15 cm)
DynaMesh®-PRP soft (1a) (03 cm x 15 cm)
DynaMesh®-PRP visible (1b) (03 cm x 15 cm)
DynaMesh®-PRP visible (2) (03cmx18cm)
DynaMesh®-PRP visible (3) (17cmx15cm)
- No presacral preparation
- Avoidance of injury to and irritation of nerves
- Low risk of defecation disorders as there is no constriction of the lesser pelvis
- Indication-related implant selection
- Very good anatomical and physiological organ positioning
- Safety through specific, standardised surgical techniques
DynaMesh®-PRP soft (03 cm x 15 cm) (1a)
DynaMesh®-PRP visible (03 cm x 15 cm) (1b)
For the surgical treatment of apical vaginal prolapse
Bilateral cervical or vaginal stump fixation as well as anterior uterus fixation with small uterus on the pectineal ligament.
Apical mesh repair
(vaginal stump / cervical stump) with
DynaMesh®-PRP soft / visible (03 cm x 15 cm)
Apical mesh repair for uterus preservation
(with small uterus) with
DynaMesh®-PRP visible (03 cm x 15 cm)
fixed uterus anterior
DynaMesh®-PRP visible (17 cm x 15 cm) (3)
DynaMesh®-PRP visible (03 cm x 18 cm) (2)
For the treatment of apical vaginal descent with simultaneous cystocele and rectocele repair
For the surgical treatment ofuterine prolapse with bilateral, posterior uterus fixation on the pectineal ligament (hysteropectopexy)
Bilateral cervical or vaginal stump fixation on the pectineal ligament. Anterior and posterior vaginal walltightening and reinforcement with extended implant structure.
Safe positioning of the uterus thanks to the special implant structure with exceptional dimensional stability and highly effective porosity.
Apical mesh repair
(vaginal stump / cervical stump) with
DynaMesh®-PRP visible (17 cm x 15 cm)
posterior and anterior fixation
Apical mesh repair for uterus preservation with
DynaMesh®-PRP visible (03 cm x 18 cm)
fixed uterus posterior