DynaMesh®

Tailored Implants Made of PVDF

DynaMesh®-LICHTENSTEIN

DynaMesh®-LICHTENSTEIN implants serve to support the tissue and stabilise the fascial structures of the inguinal region. They were specially developed for the conventional repair of inguinal hernias according to Lichtenstein and come in a size which fits the majority of patients and can therefore be used immediately without needing to be cut to size.


DynaMesh®-LICHTENSTEINProduct RangeUse and PropertiesDownloadsLiterature

lichtenstein-detail-masse

can be used both for the right and the left side


For example: inguinal hernia, left side

lichtenstein-detail

lichtenstein-elastische-sic

Less Effort
The elastic zone in the mesh, incorporated by using a special warp-knitting technique, makes it easier for the surgeon to achieve fold-free positioning of the implant.

lichtenstein-tunnelbildung

Less Risk
The special slit design enables tunnel modulation with pressure distribution.

lichtenstein-spezielle-wirk

High Tear Propagation Resistance
The high tear propagation resistance at the end point of the slit minimises the risk of mesh rupture.

When selecting the mesh size, ensure sufficient overlap!

DynaMesh®-LICHTENSTEIN 06 cm x 11 cm PV110611F3 BX = 3 pieces
DynaMesh®-LICHTENSTEIN 06 cm x 11 cm PV110611F10 BX = 10 pieces
DynaMesh®-LICHTENSTEIN 7.5 cm x 15 cm PV110715F1 BX = 1 piece
DynaMesh®-LICHTENSTEIN 7.5 cm x 15 cm PV110715F3 BX = 3 pieces
DynaMesh®-LICHTENSTEIN 7.5 cm x 15 cm PV110715F10 BX = 10 pieces
DynaMesh®-LICHTENSTEIN visible 7.5 cm x 15 cm PV170715F1 BX = 1 piece
Product DynaMesh®-LICHTENSTEIN (1)

DynaMesh®-LICHTENSTEIN visible (2)

Field of application inguinal hernia
Surgical access open
Surgical technique Lichtenstein
Mesh position anterior
Fixation sutures / adhesives
Green/black line marker
gruene_punkte
Specially Warp-knitted Selvedges
gruene_punkte
Visible technology
graue_punkte (1) / gruene_punkte (2)
Polymer (monofilament)
PVDF
Biocompatibility
gruene_punkte
Ageing resistance
gruene_punkte
Dynamometry
gruene_punkte
Tear propagation resistance
gruene_punkte
No scar plate formation
gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Brochure: DynaMesh®-LICHTENSTEIN

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Hernias

Download as PDF (english)

Als pdf herunterladen (deutsch)