DynaMesh®

Tailored Implants Made of PVDF

DynaMesh®-VASA

DynaMesh®-VASA implants have been specially developed for pelvic floor reconstruction, and particularly for reinforcing or replacing the uterosacral ligaments, in laparoscopic or open surgical technique.
The implants are used in the treatment of a prolapse of the internal genitalia, such as a vaginal stump prolapse.


DynaMesh®-VASAProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-VASA
(VAgino-SAcropexy)

The surgical technique VASA is a modified abdominal colposacropexy procedure (laparoscopic/open), in which the uterosacral ligaments are bilaterally reinforced or replaced by the implant.

DynaMesh®-IVT02 instrument for DynaMesh®-VASA in retroperitoneal tape position through laparotomic access. Reusable instrument made of surgical steel.
Length: 32 cm

  • Extraperitoneal tunnelling
  • Anatomically adapted to the pelvis
  • Eyelet on instrument tip with slanted, atraumatic edges
  • Use in laparoscopy
  • Reusable instrument

vasa-v

DynaMesh®-VASA
02 cm x 03 cm PV740203F1 BX = 1 piece
DynaMesh®-VASA
02 cm x 03 cm PV740203F3 BX = 3 pieces
Product DynaMesh®-VASA
Field of applicationt vaginal stump prolapse
Surgical access laparoscopic / open
Surgical technique colposacropexy (VASA)
bilateral
Fixation on vaginal stump
sutures
Fixation on sacrum
sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
gruene_punkte
Polymer (monofilament)
PVDF
Biocompatibility gruene_punkte
Ageing resistance gruene_punkte
Dynamometry gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes

Brochure: DynaMesh®-VASA

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PRP

DynaMesh®-PRP implants have been specially developed for pelvic floor reconstruction, in laparoscopic or open surgical technique, and serve to support and stabilise fascial structures, connective tissue and ligaments.
The implants are used in the surgical treatment of a prolapse of the vaginal/ cervical stump or uterine prolapse in the pectopexy technique.


DynaMesh®-PRPProduct RangeUse and PropertiesVideosDownloadsLiterature

Pectopexy
Bilateral Fixation on the Pectineal Ligament

Fig. left:
Apical mesh repair following hysterectomy with DynaMesh®-PRP soft / visible 03 cm x 15 cm


Pectopexy after vaginal/cervical prolapse:

  • Two implant sizes are available in the following dimensions DynaMesh®-PRP soft / visible 03 cm x 15 cm and DynaMesh®-PRP visible 03 cm x 18 cm.
  • With greatly shortened vaginas, e.g., following a radical hysterectomy, DynaMesh®-PRP visible 03 cm x 18 cm can be optionally used.

Pectopexy after vaginal/cervical prolapse with concomitant cystocele and/or rectocele: (pulsion cystocele / rectocele)

  • Additional stabilisation of the affected vaginal wall can be achieved with DynaMesh®-PRP visible 17 cm x 15 cm.

Pectopexy after uterine prolapse with uterine preservation:

  • With a normal sized uterus, DynaMesh®-PRP visible 03 cm x 18 cm should be used and fixed in place on the posterior cervix.

Pectopexy after uterine prolapse with uterine preservation:

  • With smaller uteri (below 100 g), anterior fixation of DynaMesh®-PRP soft / visible 03 cm x 15 cm can be selected as an alternative.

DynaMesh®-PRP soft (1) 03 cm x 15 cm PV540315F1 BX = 1 piece
DynaMesh®-PRP soft (1) 03 cm x 15 cm PV540315F3 BX = 1 pieces
DynaMesh®-PRP visible (2) 03 cm x 15 cm PV780315F1 BX = 1 piece

DynaMesh®-PRP visible (3) 03 cm x 18 cm PV780318F1 BX = 1 piece
DynaMesh®-PRP visible (3) 03 cm x 18 cm PV780318F3 BX = 3 pieces

DynaMesh®-PRP visible (4) 17 cm x 15 cm PV781715F1 BX = 1 piece
DynaMesh®-PRP visible (4) 17 cm x 15 cm PV781715F3 BX = 3 pieces
Product DynaMesh®-PRP soft
03 cm x 15 cm (1)

DynaMesh®-PRP visible
03 cm x 15 cm (2)

DynaMesh®-PRP visible
03 cm x 18 cm (3)

DynaMesh®-PRP visible
17 cm x 15 cm (4)

Field of application vaginal/cervical stump or uterine prolapse (1,2)

vaginal stump or uterine prolapse (3)

vaginal/cervical stump prolapse,
concomitant cystocele/rectocele (4)

Surgical access laparoscopic / open
Surgical technique pectopexy
bilateral
Fixation on vagina / cervix
sutures
Fixation on pectineal ligament sutures
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
graue_punkte (1) / gruene_punkte (2,3,4)
Polymer (monofilament)
PVDF
Biocompatibility gruene_punkte
Ageing resistance gruene_punkte
Dynamometry gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Brochure: DynaMesh®-PRP

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PRR

DynaMesh®-PRR implants have been specially developed for pelvic floor reconstruction, in laparoscopic or open surgical technique, and serve to support and stabilise fascial structures, connective tissue and ligaments.


DynaMesh®-PRRProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-PRR implants are used in the surgical treatment of the vaginal/cervical stump or uterine prolapse, as well as in the treatment of a concomitant cystocele/rectocele.

 

Application Examples:

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and anterior mesh plasty for concomitant cystocele

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and posterior mesh plasty for concomitant rectocele

Hysterosacropexy

  • unilateral
  • posterior cervical fixation

Hysterosacropexy

  • unilateral
  • posterior cervical fixation and posterior mesh plasty for concomitant rectocele

 

prr-v

DynaMesh®-PRR soft
02/04 cm x 23 cm PV360423F1 BX = 1 piece
DynaMesh®-PRR soft
02/04 cm x 23 cm PV360423F3 BX = 3 pieces
DynaMesh®-PRR visible
02/04 cm x 23 cm PV760423F1 BX = 1 piece
Product DynaMesh®-PRR soft (1)

DynaMesh®-PRR visible (2)

Field of application vaginal/cervical stump or uterine prolapse,
concomitant cystocele/rectocele
Surgical access laparoscopic / open
Surgical technique colposacropexy / cervicosacropexy / hysterosacropexy
unilateral
Fixation on vagina / cervix sutures
Fixation on sacrum sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
graue_punkte (1) / gruene_punkte (2)
Polymer (monofilament) PVDF
Biocompatibility
gruene_punkte
Ageing resistance
gruene_punkte
Dynamometry
gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Brochure: DynaMesh®-PRR

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PR

DynaMesh®-PR implants have been specially developed for pelvic floor reconstruction, in laparoscopic or open surgical technique, and serve to support and stabilise fascial structures, connective tissue and ligaments.


DynaMesh®-PRProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-PR implants are used in the surgical treatment of the vaginal/cervical stump or uterine prolapse, as well as in the treatment of a concomitant cystocele/rectocele.

 

Application Examples:

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and anterior mesh plasty for concomitant cystocele

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and posterior mesh plasty for concomitant rectocele

Hysterosacropexy

  • unilateral
  • posterior cervical fixation

Hysterosacropexy

  • unilateral
  • posterior cervical fixation and posterior mesh plasty for concomitant rectocele

 

pr-v

DynaMesh®-PR soft
04 cm x 23 cm PV500423F1 BX = 1 piece
DynaMesh®-PR soft
04 cm x 23 cm PV500423F3 BX = 3 pieces
DynaMesh®-PR visible
04 cm x 23 cm PV700423F1 BX = 1 piece
Product DynaMesh®-PR soft (1)

DynaMesh®-PR visible (2)

Field of application  vaginal/cervical stump or uterine prolapse,
concomitant cystocele/rectocele
Surgical access laparoscopic / open
Surgical technique  colposacropexy / cervicosacropexy / hysterosacropexy
unilateral
Fixation on vagina / cervix sutures
Fixation on sacrum sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
graue_punkte (1) / gruene_punkte (2)
Polymer (monofilament) PVDF
Biocompatibility
gruene_punkte
Ageing resistance
gruene_punkte
Dynamometry
gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Videos: DynaMesh®-PR soft & DynaMesh®-PR visible

Brochure: DynaMesh®-PR

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-CESA

DynaMesh®-CESA implants have been specially developed for pelvic floor reconstruction, and particularly for reinforcing or replacing the uterosacral ligaments, in laparoscopic or open surgical technique.
The implants are used in the treatment of a prolapse of the internal genitalia, such as a cervical stump prolapse.


DynaMesh®-CESAProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-CESA
(CErvico-SAcropexy)

The surgical technique CESA is a modified abdominal cervicosacropexy procedure (laparoscopic/open), in which the uterosacral ligaments are bilaterally reinforced or replaced by the implant.

DynaMesh®-IVT02 instrument for DynaMesh®-CESA in retroperitoneal tape position through laparotomic access. Reusable instrument made of surgical steel.
Length: 32 cm

  • Extraperitoneal tunnelling
  • Anatomically adapted to the pelvis
  • Eyelet on instrument tip with slanted, atraumatic edges
  • Use in laparoscopy
  • Reusable instrument

cesa-v

DynaMesh®-CESA
03 cm x 04 cm PV740404F1 BX = 1 piece
DynaMesh®-CESA
03 cm x 04 cm PV740404F3 BX = 3 pieces
Product DynaMesh®-CESA
Field of application cervical stump prolapse
Surgical access laparoscopic / open
Surgical technique cervicosacropexy (CESA)
bilateral
Fixation on cervical stump
sutures
Fixation on sacrum
sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
gruene_punkte
Polymer (monofilament)
PVDF
Biocompatibility gruene_punkte
Ageing resistance gruene_punkte
Dynamometry gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8])) 1a

gruene_punkte Applies to all product sizes

Broschure: DynaMesh®-CESA

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PRS

DynaMesh®-PRS implants have been specially developed for pelvic floor reconstruction, in laparoscopic or open surgical technique, and serve to support and stabilise fascial structures, connective tissue and ligaments.
The implants are used in the surgical treatment of the vaginal or cervical stump prolapse, as well as in the treatment of a concomitant cystocele and/or rectocele.


DynaMesh®-PRSProduct RangeUse and PropertiesVideosDownloadsLiterature

Application Examples:

DM-PRS-sacrocolpopexy-uterus-vaginal-prolaps

Colpo-/cervicosacropexy

  • unilateral

Colpo-/cervicosacropexy

  • unilateral
  • anterior/posterior mesh plasty (for concomitant cystocele/rectocele)

Colpo-/cervicosacropexy

  • unilateral

prs-soft-0216-v

DynaMesh®-PRS soft (1)
02 cm x 16 cm PV350216F1 BX = 1 piece

prs-visible-v

DynaMesh®-PRS soft (2)
03 cm x 23 cm PV350323F1 BX = 1 piece
DynaMesh®-PRS visible (3)
03 cm x 23 cm PV750323F1 BX = 1 piece

DynaMesh®-PRS visible (4)
3.3 cm x 24 cm PV750424F1 BX = 1 piece
DynaMesh®-PRS visible (4)
3.3 cm x 24 cm PV750424F10 BX = 10 pieces

DynaMesh®-PRS visible (5)
04 cm x 20 cm PV750420F1 BX = 1 piece
DynaMesh®-PRS visible (5)
04 cm x 20 cm PV750420F10 BX = 10 pieces

prs-soft-0527-v

DynaMesh®-PRS soft (6)
05 cm x 27 cm PV350527F1 BX = 1 piece
Product DynaMesh®-PRS soft
(02 cm x 16 cm) (1)
(03 cm x 23 cm) (2)
(05 cm x 27 cm) (6)

DynaMesh®-PRS visible
(03 cm x 23 cm) (3)
(3.3 cm x 24) cm (4)
(04 cm x 20 cm) (5)

Field of application vaginal/cervical stump prolapse,
concomitant cystocele/rectocele
Surgical access laparoscopic / open
Surgical technique colposacropexy / cervicosacropexy
unilateral
Fixation on vagina / cervix
sutures
Fixation on sacrum
sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
graue_punkte (1,2,6) / gruene_punkte (3,4,5)
Polymer  (monofilament)
PVDF
Biocompatibility gruene_punkte
Ageing resistance gruene_punkte
Dynamometry gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Brochure: DynaMesh®-PRS

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)