DynaMesh®

Tailored Implants Made of PVDF

DynaMesh®-VASA

DynaMesh®-VASA implants have been specially developed for pelvic floor reconstruction, and particularly for reinforcing or replacing the uterosacral ligaments, in laparoscopic or open surgical technique.
The implants are used in the treatment of a prolapse of the internal genitalia, such as a vaginal stump prolapse.


DynaMesh®-VASAProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-VASA
(VAgino-SAcropexy)

The surgical technique VASA is a modified abdominal colposacropexy procedure (laparoscopic/open), in which the uterosacral ligaments are bilaterally reinforced or replaced by the implant.

DynaMesh®-IVT02 instrument for DynaMesh®-VASA in retroperitoneal tape position through laparotomic access. Reusable instrument made of surgical steel.
Length: 32 cm

  • Extraperitoneal tunnelling
  • Anatomically adapted to the pelvis
  • Eyelet on instrument tip with slanted, atraumatic edges
  • Use in laparoscopy
  • Reusable instrument

vasa-v

DynaMesh®-VASA
02 cm x 03 cm PV740203F1 BX = 1 piece
DynaMesh®-VASA
02 cm x 03 cm PV740203F3 BX = 3 pieces
Product DynaMesh®-VASA
Field of applicationt vaginal stump prolapse
Surgical access laparoscopic / open
Surgical technique colposacropexy (VASA)
bilateral
Fixation on vaginal stump
sutures
Fixation on sacrum
sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
gruene_punkte
Polymer (monofilament)
PVDF
Biocompatibility gruene_punkte
Ageing resistance gruene_punkte
Dynamometry gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes

Brochure: DynaMesh®-VASA

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PRR

DynaMesh®-PRR implants have been specially developed for pelvic floor reconstruction, in laparoscopic or open surgical technique, and serve to support and stabilise fascial structures, connective tissue and ligaments.


DynaMesh®-PRRProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-PRR implants are used in the surgical treatment of the vaginal/cervical stump or uterine prolapse, as well as in the treatment of a concomitant cystocele/rectocele.

 

Application Examples:

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and anterior mesh plasty for concomitant cystocele

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and posterior mesh plasty for concomitant rectocele

Hysterosacropexy

  • unilateral
  • posterior cervical fixation

Hysterosacropexy

  • unilateral
  • posterior cervical fixation and posterior mesh plasty for concomitant rectocele

 

prr-v

DynaMesh®-PRR soft
02/04 cm x 23 cm PV360423F1 BX = 1 piece
DynaMesh®-PRR soft
02/04 cm x 23 cm PV360423F3 BX = 3 pieces
DynaMesh®-PRR visible
02/04 cm x 23 cm PV760423F1 BX = 1 piece
Product DynaMesh®-PRR soft (1)

DynaMesh®-PRR visible (2)

Field of application vaginal/cervical stump or uterine prolapse,
concomitant cystocele/rectocele
Surgical access laparoscopic / open
Surgical technique colposacropexy / cervicosacropexy / hysterosacropexy
unilateral
Fixation on vagina / cervix sutures
Fixation on sacrum sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
graue_punkte (1) / gruene_punkte (2)
Polymer (monofilament) PVDF
Biocompatibility
gruene_punkte
Ageing resistance
gruene_punkte
Dynamometry
gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Brochure: DynaMesh®-PRR

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PR

DynaMesh®-PR implants have been specially developed for pelvic floor reconstruction, in laparoscopic or open surgical technique, and serve to support and stabilise fascial structures, connective tissue and ligaments.


DynaMesh®-PRProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-PR implants are used in the surgical treatment of the vaginal/cervical stump or uterine prolapse, as well as in the treatment of a concomitant cystocele/rectocele.

 

Application Examples:

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and anterior mesh plasty for concomitant cystocele

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and posterior mesh plasty for concomitant rectocele

Hysterosacropexy

  • unilateral
  • posterior cervical fixation

Hysterosacropexy

  • unilateral
  • posterior cervical fixation and posterior mesh plasty for concomitant rectocele

 

pr-v

DynaMesh®-PR soft
04 cm x 23 cm PV500423F1 BX = 1 piece
DynaMesh®-PR soft
04 cm x 23 cm PV500423F3 BX = 3 pieces
DynaMesh®-PR visible
04 cm x 23 cm PV700423F1 BX = 1 piece
Product DynaMesh®-PR soft (1)

DynaMesh®-PR visible (2)

Field of application  vaginal/cervical stump or uterine prolapse,
concomitant cystocele/rectocele
Surgical access laparoscopic / open
Surgical technique  colposacropexy / cervicosacropexy / hysterosacropexy
unilateral
Fixation on vagina / cervix sutures
Fixation on sacrum sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
graue_punkte (1) / gruene_punkte (2)
Polymer (monofilament) PVDF
Biocompatibility
gruene_punkte
Ageing resistance
gruene_punkte
Dynamometry
gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Videos: DynaMesh®-PR soft & DynaMesh®-PR visible

Brochure: DynaMesh®-PR

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-CESA

DynaMesh®-CESA implants have been specially developed for pelvic floor reconstruction, and particularly for reinforcing or replacing the uterosacral ligaments, in laparoscopic or open surgical technique.
The implants are used in the treatment of a prolapse of the internal genitalia, such as a cervical stump prolapse.


DynaMesh®-CESAProduct RangeUse and PropertiesVideosDownloadsLiterature

DynaMesh®-CESA
(CErvico-SAcropexy)

The surgical technique CESA is a modified abdominal cervicosacropexy procedure (laparoscopic/open), in which the uterosacral ligaments are bilaterally reinforced or replaced by the implant.

DynaMesh®-IVT02 instrument for DynaMesh®-CESA in retroperitoneal tape position through laparotomic access. Reusable instrument made of surgical steel.
Length: 32 cm

  • Extraperitoneal tunnelling
  • Anatomically adapted to the pelvis
  • Eyelet on instrument tip with slanted, atraumatic edges
  • Use in laparoscopy
  • Reusable instrument

cesa-v

DynaMesh®-CESA
03 cm x 04 cm PV740404F1 BX = 1 piece
DynaMesh®-CESA
03 cm x 04 cm PV740404F3 BX = 3 pieces
Product DynaMesh®-CESA
Field of application cervical stump prolapse
Surgical access laparoscopic / open
Surgical technique cervicosacropexy (CESA)
bilateral
Fixation on cervical stump
sutures
Fixation on sacrum
sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
gruene_punkte
Polymer (monofilament)
PVDF
Biocompatibility gruene_punkte
Ageing resistance gruene_punkte
Dynamometry gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8])) 1a

gruene_punkte Applies to all product sizes

Broschure: DynaMesh®-CESA

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PRS

DynaMesh®-PRS implants have been specially developed for pelvic floor reconstruction, in laparoscopic or open surgical technique, and serve to support and stabilise fascial structures, connective tissue and ligaments.
The implants are used in the surgical treatment of the vaginal or cervical stump prolapse, as well as in the treatment of a concomitant cystocele and/or rectocele.


DynaMesh®-PRSProduct RangeUse and PropertiesVideosDownloadsLiterature

Application Examples:

DM-PRS-sacrocolpopexy-uterus-vaginal-prolaps

Colpo-/cervicosacropexy

  • unilateral

Colpo-/cervicosacropexy

  • unilateral
  • anterior/posterior mesh plasty (for concomitant cystocele/rectocele)

Colpo-/cervicosacropexy

  • unilateral

prs-soft-0216-v

DynaMesh®-PRS soft (1)
02 cm x 16 cm PV350216F1 BX = 1 piece

prs-visible-v

DynaMesh®-PRS soft (2)
03 cm x 23 cm PV350323F1 BX = 1 piece
DynaMesh®-PRS visible (3)
03 cm x 23 cm PV750323F1 BX = 1 piece

DynaMesh®-PRS visible (4)
3.3 cm x 24 cm PV750424F1 BX = 1 piece
DynaMesh®-PRS visible (4)
3.3 cm x 24 cm PV750424F10 BX = 10 pieces

DynaMesh®-PRS visible (5)
04 cm x 20 cm PV750420F1 BX = 1 piece
DynaMesh®-PRS visible (5)
04 cm x 20 cm PV750420F10 BX = 10 pieces

prs-soft-0527-v

DynaMesh®-PRS soft (6)
05 cm x 27 cm PV350527F1 BX = 1 piece
Product DynaMesh®-PRS soft
(02 cm x 16 cm) (1)
(03 cm x 23 cm) (2)
(05 cm x 27 cm) (6)

DynaMesh®-PRS visible
(03 cm x 23 cm) (3)
(3.3 cm x 24) cm (4)
(04 cm x 20 cm) (5)

Field of application vaginal/cervical stump prolapse,
concomitant cystocele/rectocele
Surgical access laparoscopic / open
Surgical technique colposacropexy / cervicosacropexy
unilateral
Fixation on vagina / cervix
sutures
Fixation on sacrum
sutures / tacks
Specially Warp-knitted Selvedges
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
Visible technology
graue_punkte (1,2,6) / gruene_punkte (3,4,5)
Polymer  (monofilament)
PVDF
Biocompatibility gruene_punkte
Ageing resistance gruene_punkte
Dynamometry gruene_punkte
Tear propagation resistance gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Brochure: DynaMesh®-PRS

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Female Pelvic Organ Prolapse

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-IPST

DynaMesh®-IPST implants are used in the prophylaxis and therapy of hernias and fascial defects in the abdominal wall after ostomy as well as to reinforce connective tissue structures and prevent prolapse of the diverted portion of the intestines.


DynaMesh®-IPSTProduct RangeUse and PropertiesVideosDownloadsLiterature

 

 

Handling
The implant is made from a single piece of mesh for a seamless junction with the elastic funnel. DynaMesh®-IPST is a three-dimensional preshaped implant providing excellent
elasticity and flexibility – which facilitates stomaplasty preparation for the surgeon.

 

 

ipst-intraperitoneal

 

 

Elastic Funnel
The dual-layer composite structure promotes ingrowth into the abdominal wall while at the same time reducing the risks of adhesions on the visceral side.

The elastic funnel with no sharp selvedges leads to secure integration of the terminal segment of bowel and reliably prevents parastomal hernia formation [15,61].

 

 

 

 

Placement
DynaMesh®-IPST-R can be placed without detaching the stoma from the abdominal wall.

The prefabricated slit makes it easier to place the mesh implant around the terminal section of the bowel.

 

 

Repair and Prevention of Parastomal Hernia

When selecting the mesh size, ensure sufficient overlap!

DynaMesh®-IPST Funnel height: 4.0 cm ø 02 cm x 15 cm x 15 cm (L4) IP072415F1 BX = 1 piece
DynaMesh®-IPST Funnel height: 2.5 cm ø 2 cm x 15 cm x 15 cm IP070215F1 BX = 1 piece
DynaMesh®-IPST Funnel height: 2.5 cm ø 2 cm x 25 cm x 25 cm IP070225F1 BX = 1 piece
DynaMesh®-IPST Funnel height: 2.5 cm ø 3 cm x 16 cm x 16 cm IP070316F1 BX = 1 piece
DynaMesh®-IPST Funnel height: 2.5 cm ø 4 cm x 17 cm x 17 cm IP070417F1 BX = 1 piece
DynaMesh®-IPST visible Funnel height: 4.0 cm ø 02 cm x 15 cm x 15 cm (L4) IP082415F1 BX = 1 piece
DynaMesh®-IPST visible Funnel height: 2.5 cm ø 2 cm x 15 cm x 15 cm IP080215F1 BX = 1 piece
DynaMesh®-IPST visible Funnel height: 2.5 cm ø 3 cm x 16 cm x 16 cm IP080316F1 BX = 1 piece
DynaMesh®-IPST-D visible Funnel height: 4.0 cm ø 02 cm x 30 cm x 30 cm (L4) left IP082431F1 BX = 1 piece
DynaMesh®-IPST-D visible Funnel height: 4.0 cm ø 02 cm x 30 cm x 30 cm (L4) right IP082432F1 BX = 1 piece

Important: Side specificity (left-sided/right-sided stoma)


Repair of Parastomal Hernia

When selecting the mesh size, ensure sufficient overlap!

DynaMesh®-IPST-R Funnel height: 3.5 cm ø 03 cm x 16 cm x 16 cm (L3.5) IP103316F1 BX = 1 piece
DynaMesh®-IPST-R visible Funnel height: 3.5 cm Sø 03 cm x 16 cm x 16 cm (L3.5) IP113316F1 BX = 1 piece
Product DynaMesh®-IPST (1)

DynaMesh®-IPST visible (2)

 

DynaMesh®-IPST-D visible (3)

 

DynaMesh®-IPST-R (4)

DynaMesh®-IPST-R visible (5)

Field of application parastomal hernia
(repair (1-5) / prevention (1-3))
Surgical access laparoscopic / open
Surgical technique IPOM
Mesh position intraperitoneal
Fixation sutures / tacks
Green marker thread
gruene_punkte
PVDF barrier
gruene_punkte
Visible technology
graue_punkte (1,4) / gruene_punkte (2,3,5)
Dual-component structure PVDF monofilament > 85 %
PP monofilament
Biocompatibility
gruene_punkte
Ageing resistance
gruene_punkte
Dynamometry
gruene_punkte
Tear propagation resistance
gruene_punkte
No scar plate formation
gruene_punkte
Classification (Klinge’s classification [8])
gruene_punkte

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Alle DynaMesh®-IPST (1-5) implants are used both in laparoscopy and in open surgery. Common applications follow the intraperitoneal onlay mesh technique since the mesh is composed of different materials, which allows intraperitoneal application.

Alle DynaMesh®-IPST (1-5) implants have a parietal and a visceral side. The parietal side is marked with green thread ends and consists of PVDF and a small portion of PP on the surface, while the visceral side consists of PVDF on the surface.

DynaMesh®-IPST-D visible (3) implants are used for the repair as well as the prevention of parastomal hernia with particularly large overlap in cranial and medial direction with intraperitoneal mesh position
(side specificity: left-sided / right-sided stoma).

DynaMesh®-IPST-R (4,5) implants are used to repair the parastomal hernia without detachment of the stoma from the abdominal wall with intraperitoneal mesh position. The prefabricated slit facilitates placement of the mesh implant around the terminal segment of the bowel.

Brochure: DynaMesh®-IPST

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Hernias

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-IPOM

DynaMesh®-IPOM implants are designed for soft tissue reinforcement and soft tissue bridging of the fascial and connective tissue structures of the abdominal wall as part of surgical treatment for epigastric hernias, umbilical or incisional hernias, and parastomal hernias following ostomy surgery.


DynaMesh®-IPOMProduct RangeUse and PropertiesVideosDownloadsLiterature

Dual-Layer Composite Mesh
DynaMesh®-IPOM is a dual-component structure specifically developed for the IPOM technique and consists mainly of high-purity PVDF and a small proportion of polypropylene (PP). The parietal side (PP) promotes rapid and safe ingrowth into the abdominal wall. The PVDF layer on the visceral side forms a barrier to the intestines. PVDF demonstrably decreases the risks of adhesions compared with polypropylene [11] and thus reduces the risk of intestinal erosions. If implantation of several meshes is required (for example, the sandwich technique [9]), the open-pore structure means that implants can easily be overlapped.

 

Correct Orientation
The parietal side (PP component) has a green marker thread and must face the abdominal wall. The marker thread is located on the front surface and simultaneously shows the correct direction of the elasticity in the craniocaudal direction.

DM-IPOM_Fold-free-mesh-positioning

Fold-free mesh positioning after draining the pneumoperitoneum


DM-IPOM_intraoperativei

Intraoperative view

 

 

Advantages for the Patients
The open-pore mesh construction facilitates the break-down of seroma and reduces scar plate formation.
Minimal mesh shrinkage is achieved and long-term surgical success with high patient comfort is ensured [9-14] through the open-pore and elastic mesh construction made from PVDF, which offers long-term stability.

 

Abdominal Wall Hernia
Recommended sizes for the surgical treatment of abdominal wall hernias.

When selecting the mesh size, ensure sufficient overlap!

DynaMesh®-IPOM d 12 cm round IP070012F1 BX = 1 piece
DynaMesh®-IPOM d 12 cm round IP070012F3 BX = 3 pieces
DynaMesh®-IPOM 10 cm x 15 cm IP071015F1 BX = 1 piece
DynaMesh®-IPOM 10 cm x 15 cm IP071015F3 BX = 3 pieces
DynaMesh®-IPOM 15 cm x 15 cm IP071515F1 BX = 1 piece
DynaMesh®-IPOM 15 cm x 15 cm IP071515F3 BX = 3 pieces
DynaMesh®-IPOM 15 cm x 20 cm IP071520F1 BX = 1 piece
DynaMesh®-IPOM 15 cm x 20 cm IP071520F3 BX = 3 pieces
DynaMesh®-IPOM 20 cm x 20 cm IP072020F1 BX = 1 piece
DynaMesh®-IPOM 20 cm x 25 cm IP072025F1 BX = 1 piece
DynaMesh®-IPOM 20 cm x 30 cm IP072030F1 BX = 1 piece
DynaMesh®-IPOM 20 cm x 30 cm IP072030F3 BX = 3 pieces
DynaMesh®-IPOM 28 cm x 37 cm IP072837F1 BX = 1 piece
DynaMesh®-IPOM 30 cm x 30 cm IP073030F1 BX = 1 piece
DynaMesh®-IPOM 30 cm x 45 cm IP073045F1 BX = 1 piece
DynaMesh®-IPOM visible 30 cm x 30 cm IP083030F1 BX = 1 piece

Umbilical Hernia
Recommended sizes for the surgical treatment of umbilical hernias.

When selecting the mesh size, ensure sufficient overlap!

DynaMesh®-IPOM
07 cm x 06 cm IP070706F5 BX = 5 pieces
DynaMesh®-IPOM d 12 cm round IP070012F1 BX = 1 piece
DynaMesh®-IPOM d 12 cm round IP070012F3 BX = 3 pieces
DynaMesh®-IPOM 10 cm x 15 cm IP071015F1 BX = 1 piece
DynaMesh®-IPOM 10 cm x 15 cm IP071015F3 BX = 3 pieces
DynaMesh®-IPOM 15 cm x 15 cm IP071515F1 BX = 1 piece
DynaMesh®-IPOM 15 cm x 15 cm IP071515F3 BX = 3 pieces
Product DynaMesh®-IPOM (1)

DynaMesh®-IPOM visible (2)

Field of application abdominal wall hernia / umbilical hernia
Surgical access laparoscopic / open
Surgical technique IPOM
Mesh position intraperitoneal
Fixation sutures / tacks
Green marker thread
gruene_punkte
PVDF barrier
gruene_punkte
Visible technology
graue_punkte (1) / gruene_punkte (2)
Dual-component structure
PVDF monofilament > 85 %
PP monofilament
Biocompatibility
gruene_punkte
Ageing resistance
gruene_punkte
Dynamometry
gruene_punkte
Tear propagation resistance
gruene_punkte
No scar plate formation
gruene_punkte
Classification (Klinge’s classification [8]) 1a

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply


DynaMesh®-IPOM implants have a parietal side and a visceral side.
The parietal side is identified by green-marked filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

Brochure: DynaMesh®-IPOM

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh® Catalogue

Als pdf herunterladen (deutsch)

Download as PDF (english)

References: Implant Material / Product Design / DynaMesh® visible / Implant Fixation

Download as PDF (english)

Als pdf herunterladen (deutsch)

References: Hernias

Download as PDF (english)

Als pdf herunterladen (deutsch)