DynaMesh®

Tailored Implants Made of PVDF

DynaMesh®-CICAT

DynaMesh®-CICAT and DynaMesh®-CICAT visible implants are intended for the surgical treatment of epigastric hernias, umbilical or incisional hernias, and the prevention of incisional hernias, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the abdominal wall defect.


DynaMesh®-CICATProduct RangeUse and PropertiesVideosFurther Product Information

Anti-Slip Surface
The devices have an anti-slip surface that ensures stable positioning of the mesh with reduced fixation compared to other devices available on the market. [132PB, 133PB, 134]

Dynamometric Positioning
For the correct dynamometric positioning of the device, ensure that the green or black marking strips are in a cranio-caudal orientation.

High Effective Porosity
The devices have a high effective porosity, which is known to reduce inflammation and the risk of excessive scar formation. [103P, TR33, TR35]

 

The device must not be placed partially or completely intraperitoneally.

 

 

[#] Reference “#”(see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests

When selecting and cutting the device, sufficient defect/scar overlap must be ensured to minimise the likelihood of the hernia recurring. With epigastric hernias and umbilical hernias, it is crucial to overlap the hernia orifice, whereas with incisional hernias it is crucial to overlap the scar tissue.

DynaMesh®-CICAT d 10 cm round PV090010F1/F3
DynaMesh®-CICAT 05 cm x 06 cm PV090506F1/F5
DynaMesh®-CICAT 10 cm x 10 cm PV091010F1/F3/F5
DynaMesh®-CICAT 15 cm x 15 cm PV091515F1/F3
DynaMesh®-CICAT 30 cm x 30 cm PV093030F1/F2
DynaMesh®-CICAT 10 cm x 15 cm PV091015F5
DynaMesh®-CICAT 10 cm x 35 cm PV091035F1/F2
DynaMesh®-CICAT 15 cm x 25 cm PV091525F1/F2/F5
DynaMesh®-CICAT 15 cm x 30 cm PV091530F1/F2/F5
DynaMesh®-CICAT 15 cm x 60 cm PV091560F1
DynaMesh®-CICAT 18 cm x 40 cm PV091840F2
DynaMesh®-CICAT 20 cm x 30 cm PV092030F1/F2/F5
DynaMesh®-CICAT 30 cm x 45 cm PV093045F1/F3
DynaMesh®-CICAT 45 cm x 60 cm PV094560F1
DynaMesh®-CICAT 27 cm x 15 cm PV092715F1/F2
DynaMesh®-CICAT
40 cm x 20 cm PV094020F1/F2
DynaMesh®-CICAT visible d 10 cm round PV160010F3
DynaMesh®-CICAT visible 05 cm x 06 cm PV160506F1/F5
DynaMesh®-CICAT visible 10 cm x 10 cm PV161010F3
DynaMesh®-CICAT visible 15 cm x 15 cm PV161515F3
DynaMesh®-CICAT visible 07 cm x 35 cm PV160735F1/F5
DynaMesh®-CICAT visible 10 cm x 35 cm PV161035F2
DynaMesh®-CICAT visible 15 cm x 25 cm PV161525F2/F5
DynaMesh®-CICAT visible 15 cm x 30 cm PV161530F2
DynaMesh®-CICAT visible 18 cm x 40 cm PV161840F2
DynaMesh®-CICAT visible 20 cm x 30 cm PV162030F1/F2/F5
DynaMesh®-CICAT visible 30 cm x 45 cm PV163045F1/F3
DynaMesh®-CICAT visible 45 cm x 60 cm PV164560F1
DynaMesh®-CICAT visible 40 cm x 20 cm PV164020F1
FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
size: laterolateral x craniocaudal
Product DynaMesh®-CICAT (1)
DynaMesh®-CICAT visible (2)
Surgical Treatment Epigastric Hernias / Umbilical Hernias / Incisional Hernias
Prevention: Incisional Hernia
Surgical Approach Minimally Invasive / Open
Mesh Position Extraperitoneal
(onlay, sublay and/or preperitoneal)
Fixation Sutures / Tacks / Tissue Adhesives
Marking Strips Green (1) / Black (2)
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament)
PVDF
Biocompatibility
gruene_punkte [TR1]
Ageing Resistance
gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Dynamometric Properties
gruene_punkte [TR38, 128P, 129]
Tear Propagation Resistance
gruene_punkte [TR31]
Anti-Slip Surface
gruene_punkte [132PB, 133PB, 134]
Effective Porosity gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR33, TR35]
Klinge’s Mesh Classification Class 1a [102P, TR33, TR35]
DynaMesh®-CICAT implants must be placed extraperitoneally in onlay, sublay and/or preperitoneal mesh position.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

Videos: DynaMesh®-CICAT











DynaMesh® Catalogue

Download as PDF (english)

Als pdf herunterladen (deutsch)