DynaMesh®-SIS
DynaMesh®-SIS implants are designed as a midurethral sling for soft tissue reinforcement of the pelvic floor as part of the surgical treatment of stress urinary incontinence caused by a hypermobile urethra and/or intrinsic sphincter deficiency.
DynaMesh®-SISProduct RangeUse and PropertiesVideosDownloadsReferencesinternal test-report references
Retropubic
(inside-out / bottom-up)
Transobturator
(inside-out & outside-in)
DynaMesh®-SIS implants are positioned using the inside-out technique in case of a retropubic tape position, and using the outsidein or inside-out technique in case of a transobturator tape position.
DynaMesh®-SIS implants have a thread on both ends of the sling, which aids fixation to the surgical instrument.
Several reusable instruments are available separately to assist the positioning of DynaMesh®-SIS implants:
DynaMesh®-ISR01:
Instrument for retropubic positioning of DynaMesh®-SIS implants through transvaginal access using the inside-out technique.
Diameter: 5-7 cm
DynaMesh®-IST01/-IST02/-IST03:
Instrument set consisting of two instruments (right and left side) for transobturator positioning through transvaginal access using the inside-out or outside-in technique.
DynaMesh®-IVT01:
Instrument for transobturator positioning through transvaginal access using the outside-in technique.
DynaMesh®-SIS |
01 cm x 50 cm | PV211056F1 | BX = 1 piece |
DynaMesh®-SIS |
01 cm x 50 cm | PV211056F3 | BX = 3 pieces |
DynaMesh®-SIS soft |
01 cm x 50 cm | PV411056F1 | BX = 1 piece |
DynaMesh®-SIS soft |
01 cm x 50 cm | PV411056F3 | BX = 3 pieces |
DynaMesh®-SIS visible |
01 cm x 50 cm | PV471056F1 | BX = 1 piece |
DynaMesh®-SIS visible |
01 cm x 50 cm | PV471056F3 | BX = 3 pieces |
Product | DynaMesh®-SIS (1)
DynaMesh®-SIS soft (2) DynaMesh®-SIS visible (3) |
Field of application | stress urinary incontinence (SUI) |
Surgical access | transvaginal |
Surgical technique | TVT – retropubic – inside-out / TOT – transobturator – inside-out – outside-in |
Fixation | none |
Specially Warp-knitted Selvedges |
![]() |
Shape stability [TR1,TR12] |
![]() |
Defined elasticity [TR10] |
![]() |
Visible technology |
![]() ![]() |
Polymer (monofilament) |
PVDF
|
Biocompatibility [1A,2A,4A,68A,100A,TR1] |
![]() |
Tear propagation resistance [101,2A,5B,52B,93A,27A] |
![]() |
Classification (Klinge’s classification [8]) [TR11] |
![]() |
Applies to all product sizes
Does not apply
[#] Reference “#” (see “References”)
[#A] Reference “#” (see “References”), “A”: limitation “animal trial”
[#B] Reference “#” (see “References”), “B”: limitation “in-vitro trial”
[TR#] Internal test-report (see “internal test-report references”