DynaMesh®

Tailored Implants Made of PVDF

DynaMesh®-PR

DynaMesh®-PR soft and DynaMesh®-PR visible implants are intended to be used as bridging material and reinforce the soft tissue of the vaginal walls as part of surgical treatment for apical pelvic organ prolapse.


DynaMesh®-PRProduct RangeUse and PropertiesVideosFurther Product Information

The target patient group are fully-grown female patients with apical pelvic organ prolapse (of the uterus, vaginal or cervical stump).

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and anterior mesh plasty for concomitant cystocele

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and posterior mesh plasty for concomitant rectocele

Hysterosacropexy

  • unilateral
  • posterior cervical fixation

Hysterosacropexy

  • unilateral
  • posterior cervical fixation and posterior mesh plasty for concomitant rectocele

 

DynaMesh®-PR soft
04 cm x 23 cm PV500423F1/F3/F5
DynaMesh®-PR visible 04 cm x 23 cm PV700423F1
FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
Product DynaMesh®-PR soft (1)
DynaMesh®-PR visible (2)
Surgical Treatment Apical Pelvic Organ Prolapse (Uterus / Vaginal Stump / Cervical Stump)
Surgical Approach Minimally Invasive / Open
Surgical Technique Sacropexy
Fixation – Anterior longitudinal ligament: non-absorbable suture or tacks
– Vaginal stump or cervix: interrupted non-absorbable suture (preferably)
Smooth Warp-Knitted Selvedges gruene_punkte
Defined Elasticity
gruene_punkte [TR110]
Visible Technology
graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament) PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR111]
Klinge’s Mesh Classification Class 1a [102P, TR111]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests