DynaMesh®-IPST
DynaMesh®-IPST implants are used in the prophylaxis and therapy of hernias and fascial defects in the abdominal wall after ostomy as well as to reinforce connective tissue structures and prevent prolapse of the diverted portion of the intestines.
DynaMesh®-IPSTProduct RangeUse and PropertiesVideosDownloadsLiterature
Handling
The implant is made from a single piece of mesh for a seamless junction with the elastic funnel. DynaMesh®-IPST is a three-dimensional preshaped implant providing excellent
elasticity and flexibility – which facilitates stomaplasty preparation for the surgeon.
Elastic Funnel
The dual-layer composite structure promotes ingrowth into the abdominal wall while at the same time reducing the risks of adhesions on the visceral side.
The elastic funnel with no sharp selvedges leads to secure integration of the terminal segment of bowel and reliably prevents parastomal hernia formation [15,61].
Placement
DynaMesh®-IPST-R can be placed without detaching the stoma from the abdominal wall.
The prefabricated slit makes it easier to place the mesh implant around the terminal section of the bowel.
Repair and Prevention of Parastomal Hernia
When selecting the mesh size, ensure sufficient overlap!
DynaMesh®-IPST | ![]() |
Funnel height: 4.0 cm | ø 02 cm x 15 cm x 15 cm (L4) | IP072415F1 | BX = 1 piece |
DynaMesh®-IPST | ![]() |
Funnel height: 2.5 cm | ø 2 cm x 15 cm x 15 cm | IP070215F1 | BX = 1 piece |
DynaMesh®-IPST | ![]() |
Funnel height: 2.5 cm | ø 2 cm x 25 cm x 25 cm | IP070225F1 | BX = 1 piece |
DynaMesh®-IPST | ![]() |
Funnel height: 2.5 cm | ø 3 cm x 16 cm x 16 cm | IP070316F1 | BX = 1 piece |
DynaMesh®-IPST | ![]() |
Funnel height: 2.5 cm | ø 4 cm x 17 cm x 17 cm | IP070417F1 | BX = 1 piece |
DynaMesh®-IPST visible | ![]() |
Funnel height: 4.0 cm | ø 02 cm x 15 cm x 15 cm (L4) | IP082415F1 | BX = 1 piece |
DynaMesh®-IPST visible | ![]() |
Funnel height: 2.5 cm | ø 2 cm x 15 cm x 15 cm | IP080215F1 | BX = 1 piece |
DynaMesh®-IPST visible | ![]() |
Funnel height: 2.5 cm | ø 3 cm x 16 cm x 16 cm | IP080316F1 | BX = 1 piece |
DynaMesh®-IPST-D visible | ![]() |
Funnel height: 4.0 cm | ø 02 cm x 30 cm x 30 cm (L4) left | IP082431F1 | BX = 1 piece |
DynaMesh®-IPST-D visible | ![]() |
Funnel height: 4.0 cm | ø 02 cm x 30 cm x 30 cm (L4) right | IP082432F1 | BX = 1 piece |
Important: Side specificity (left-sided/right-sided stoma)
Repair of Parastomal Hernia
When selecting the mesh size, ensure sufficient overlap!
DynaMesh®-IPST-R | ![]() |
Funnel height: 3.5 cm | ø 03 cm x 16 cm x 16 cm (L3.5) | IP103316F1 | BX = 1 piece |
DynaMesh®-IPST-R visible | ![]() |
Funnel height: 3.5 cm | Sø 03 cm x 16 cm x 16 cm (L3.5) | IP113316F1 | BX = 1 piece |
Product | DynaMesh®-IPST (1)
DynaMesh®-IPST visible (2)
DynaMesh®-IPST-D visible (3)
DynaMesh®-IPST-R (4) DynaMesh®-IPST-R visible (5) |
Field of application | parastomal hernia (repair (1-5) / prevention (1-3)) |
Surgical access | laparoscopic / open |
Surgical technique | IPOM |
Mesh position | intraperitoneal |
Fixation | sutures / tacks |
Green marker thread |
![]() |
PVDF barrier |
![]() |
Visible technology |
![]() ![]() |
Dual-component structure | PVDF monofilament > 85 % PP monofilament |
Biocompatibility |
![]() |
Ageing resistance |
![]() |
Dynamometry |
![]() |
Tear propagation resistance |
![]() |
No scar plate formation |
![]() |
Classification (Klinge’s classification [8]) |
![]() |
Applies to all product sizes
Does not apply
Alle DynaMesh®-IPST (1-5) implants are used both in laparoscopy and in open surgery. Common applications follow the intraperitoneal onlay mesh technique since the mesh is composed of different materials, which allows intraperitoneal application.
Alle DynaMesh®-IPST (1-5) implants have a parietal and a visceral side. The parietal side is marked with green thread ends and consists of PVDF and a small portion of PP on the surface, while the visceral side consists of PVDF on the surface.
DynaMesh®-IPST-D visible (3) implants are used for the repair as well as the prevention of parastomal hernia with particularly large overlap in cranial and medial direction with intraperitoneal mesh position
(side specificity: left-sided / right-sided stoma).
DynaMesh®-IPST-R (4,5) implants are used to repair the parastomal hernia without detachment of the stoma from the abdominal wall with intraperitoneal mesh position. The prefabricated slit facilitates placement of the mesh implant around the terminal segment of the bowel.