DynaMesh®

Tailored Implants Made of PVDF

DynaMesh®-VASA

DynaMesh®-VASA is intended to be used as bridging material and/or ligament reinforcement of the uterosacral ligaments as part of surgical treatment for apical pelvic organ prolapse.


DynaMesh®-VASAProduct RangeUse and PropertiesVideosFurther Product Information

DynaMesh®-VASA

The device is used for bilateral sacropexy. In bilateral sacropexy, both of the uterosacral ligaments are reconstructed along their original course.


DynaMesh®-IVT01


DynaMesh®-IVT02

The following reusable instruments for retroperitoneal insertion are available separately for positioning:

DynaMesh®-IVT01 and DynaMesh®-IVT02

 

DynaMesh®-VASA
02 cm x 03 cm PV740203F1/F3
  FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
Product DynaMesh®-VASA
Surgical Treatment Apical Pelvic Organ Prolapse (Uterus / Vaginal Stump / Cervical Stump)
Surgical Approach Minimally Invasive / Open
Surgical Technique Bilateral Sacropexy (reconstruction of both uterosacral ligaments)
Fixation – Anterior longitudinal ligament: non-absorbable suture or tacks
– Vaginal stump or cervix: non-absorbable suture
Smooth Warp-Knitted Selvedges
gruene_punkte
Defined Elasticity
gruene_punkte [TR100]
Visible Technology
gruene_punkte
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w)
Polymer (Monofilament) PVDF
Biocompatibility gruene_punkte [TR1]
Ageing Resistance gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR101]
Klinge’s Mesh Classification Class 1a
[102P, TR101]
gruene_punkte Applicable
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh® Catalogue

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PRR

DynaMesh®-PRR soft and DynaMesh®-PRR visible implants are intended to be used as bridging material and reinforce the soft tissue of the vaginal walls as part of surgical treatment for apical pelvic organ prolapse.


DynaMesh®-PRRProduct RangeUse and PropertiesVideosFurther Product Information

The target patient group are fully-grown female patients with apical pelvic organ prolapse (of the uterus, vaginal or cervical stump).

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and anterior mesh plasty for concomitant cystocele

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and posterior mesh plasty for concomitant rectocele

Hysterosacropexy

  • unilateral
  • posterior cervical fixation

Hysterosacropexy

  • unilateral
  • posterior cervical fixation and posterior mesh plasty for concomitant rectocele

 

DynaMesh®-PRR soft
02/04 cm x 23 cm PV360423F1/F3
DynaMesh®-PRR visible
02/04 cm x 23 cm PV760423F1
FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
Product DynaMesh®-PRR soft (1)
DynaMesh®-PRR visible (2)
Surgical Treatment Apical Pelvic Organ Prolapse (Uterus / Vaginal Stump / Cervical Stump)
Surgical Approach Minimally Invasive / Open
Surgical Technique Sacropexy
Fixation – Anterior longitudinal ligament: non-absorbable suture or tacks
– Vaginal stump or cervix: interrupted non-absorbable suture (preferably)
Smooth Warp-Knitted Selvedges gruene_punkte
Defined Elasticity
gruene_punkte [TR110]
Visible Technology
graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament) PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR111]
Klinge’s Mesh Classification Class 1a [102P, TR111]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh® Catalogue

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PR

DynaMesh®-PR soft and DynaMesh®-PR visible implants are intended to be used as bridging material and reinforce the soft tissue of the vaginal walls as part of surgical treatment for apical pelvic organ prolapse.


DynaMesh®-PRProduct RangeUse and PropertiesVideosFurther Product Information

The target patient group are fully-grown female patients with apical pelvic organ prolapse (of the uterus, vaginal or cervical stump).

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and anterior mesh plasty for concomitant cystocele

Colpo-/cervicosacropexy

  • unilateral
  • fixation on vaginal/cervical stump and posterior mesh plasty for concomitant rectocele

Hysterosacropexy

  • unilateral
  • posterior cervical fixation

Hysterosacropexy

  • unilateral
  • posterior cervical fixation and posterior mesh plasty for concomitant rectocele

 

DynaMesh®-PR soft
04 cm x 23 cm PV500423F1/F3/F5
DynaMesh®-PR visible 04 cm x 23 cm PV700423F1
FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
Product DynaMesh®-PR soft (1)
DynaMesh®-PR visible (2)
Surgical Treatment Apical Pelvic Organ Prolapse (Uterus / Vaginal Stump / Cervical Stump)
Surgical Approach Minimally Invasive / Open
Surgical Technique Sacropexy
Fixation – Anterior longitudinal ligament: non-absorbable suture or tacks
– Vaginal stump or cervix: interrupted non-absorbable suture (preferably)
Smooth Warp-Knitted Selvedges gruene_punkte
Defined Elasticity
gruene_punkte [TR110]
Visible Technology
graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament) PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR111]
Klinge’s Mesh Classification Class 1a [102P, TR111]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

Videos: DynaMesh®-PR soft & DynaMesh®-PR visible

DynaMesh® Catalogue

Download as PDF (english)

Als pdf herunterladen (deutsch)

DynaMesh®-PRS

DynaMesh®-PRS soft and DynaMesh®-PRS visible implants are intended to be used as bridging material and reinforce the soft tissue of the vaginal walls as part of surgical treatment for apical pelvic organ prolapse.


DynaMesh®-PRSProduct RangeUse and PropertiesVideosFurther Product Information

Application Examples:

DM-PRS-sacrocolpopexy-uterus-vaginal-prolaps

Colpo-/cervicosacropexy

  • unilateral

Colpo-/cervicosacropexy

  • unilateral
  • anterior/posterior mesh plasty (for concomitant cystocele/rectocele)

Colpo-/cervicosacropexy

  • unilateral
DynaMesh®-PRS soft
02 cm x 16 cm PV350216F1
DynaMesh®-PRS soft 03 cm x 23 cm PV350323F1
DynaMesh®-PRS visible
03 cm x 23 cm PV750323F1/F10
DynaMesh®-PRS visible 3.3 cm x 24 cm PV750424F1/F10
DynaMesh®-PRS visible 04 cm x 20 cm PV750420F1/F10
DynaMesh®-PRS soft
05 cm x 27 cm PV350527F1
  FX = X unit(s)/box (e.g. F3 = 3 unit(s)/box)
Product DynaMesh®-PRS soft (1)
DynaMesh®-PRS visible (2)
Surgical Treatment Apical Pelvic Organ Prolapse (Vaginal Stump / Cervical Stump)
Surgical Approach Minimally Invasive / Open
Surgical Technique Sacropexy
Fixation – Anterior longitudinal ligament: non-absorbable suture or tacks
– Vaginal/cervical stump and vaginal walls: interrupted non-absorbable suture
Smooth Warp-Knitted Selvedges gruene_punkte
Defined Elasticity
gruene_punkte [TR130]
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials
– Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2)
Polymer (Monofilament)
PVDF
Biocompatibility gruene_punkte[TR1]
Ageing Resistance gruene_punkte [2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR132]
Klinge’s Mesh Classification Class 1a [102P, TR132]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh® Catalogue

Download as PDF (english)

Als pdf herunterladen (deutsch)